1. A large enough site should be selected according to the actual size of the nitrogen generator. The distance between it and the surrounding environment should be kept more than 1 meter, which is for the convenience of operation.
2. The installation site must have good ventilation and less dust.
3. It cannot be installed in a corrosive environment.
4. The muffler (the exhaust gas outlet of the PSA nitrogen generator) can be installed indoors or outdoors. When the air compressor and the nitrogen generator are in the same room, the muffler should be installed outdoors to avoid affecting the nitrogen production.
5. The nitrogen generator should be placed in a place with poor ventilation, and the muffler should be installed outdoors.
6. If the muffler is installed outdoors, the muffler installed outdoors should be equipped with rainproof facilities. Pay attention to its placement height not higher than the exhaust gas outlet. Otherwise, the pipeline sewage will not only be unable to be discharged, but it will easily cause the sewage to pour back.
7. Notes on power supply installation:
(1) The power supply should be configured according to the calibrated voltage (V), current (A) and number of phases;
(2) The grid voltage should be within the range of AC ±10%;
(3) In order to ensure safety, the safety must be effectively grounded;
(4) The installation of nitrogen generator must be carried out in accordance with the relevant regulations and requirements of the state.