Precautions for operation and use of industrial oxygen concentrator and state during operation

Release time: 2022-09-01

The industrial oxygen generator has a great function in industrial production. It has a wide range of applications, involving many processes, resulting in a lot of characteristics of industrial oxygen generators. The scope of application includes smelting process, chemical industry, machinery industry, energy industry, and defense industry. Wait, today Xiaobian will explain to you the precautions for the operation and use of the industrial oxygen generator and the status of the equipment when it is running.
First, Precautions for the operation and use of industrial oxygen concentrators
1. Adjust the pressure regulating valve in front of the flowmeter and the oxygen production valve behind the flowmeter according to the gas pressure and gas consumption. Do not increase the flow at will to ensure the normal operation of the equipment.
2. The opening of the air inlet valve and the oxygen gas production valve should not be too large to ensure the best purity.
3. The valve adjusted by the debugging personnel should not be rotated at will, so as not to affect the purity.
4. Do not move the electrical components in the electric control cabinet at will, and do not disassemble the pneumatic pipeline valves at will.
5. The operator should regularly check the four pressure gauges on the machine, and make a daily record of the pressure changes for equipment failure analysis.
6. Regularly observe the outlet pressure, flow meter indication and oxygen purity, compare with the value on the performance page, and solve the problem in time.
7. Maintain and maintain according to the technical requirements of air compressors, refrigerated dryers and filters to ensure air quality. Air compressors and refrigeration dryers must be overhauled at least once a year, and wearing parts must be replaced and maintained in accordance with equipment maintenance and maintenance regulations; filter elements must be replaced in time.
8. Maintenance can only be carried out when the equipment is maintained and the gas must be cut off (the pressure gauge of the gas storage tank shows zero).
9. Complete the daily record form.

image.png


Second, The state of industrial oxygen production equipment during normal operation
1. The power indicator light is on, and the left suction, pressure equalization, and right suction indicators light up circularly to indicate the oxygen production process.
2. When the left suction indicator light is on, the pressure of the left adsorption tower gradually rises to the highest from the equilibrium pressure when the pressure is equalized, while the pressure of the right adsorption tower gradually decreases to zero from the equilibrium pressure when the pressure is equalized. When the pressure equalization indicator light is on, the pressure of the left and right adsorption towers will gradually reach a balance between the two.
3. When the right suction indicator light is on, the pressure of the right adsorption tower gradually rises to the highest from the equilibrium pressure when the pressure is equalized, while the pressure of the left adsorption tower gradually decreases to zero from the equilibrium pressure when the pressure is equalized.
4. The oxygen outlet pressure is indicated as normal gas pressure, and the pressure will fluctuate slightly during use, but the change should not be too large.
5. The flow indication of the flow meter should be basically stable, the fluctuation should not be too large, and the indication value of the flow meter should not be greater than the rated gas production of the oxygen production equipment.
6. The indicated value of the oxygen meter should not be less than the rated purity of the oxygen generator, and there may be a little fluctuation, but it should not fluctuate too much.